If you are calling the repairman to relight a pilot light that went out, your repairman is ripping you off. Rheem gets my congrats for the great support and fast shipping. For showers to operate correctly, it’s necessary to store your hot water at a minimum of 60°C. Rheem gets my congrats for the great support and fast shipping. See how to safely relight different Rheem gas hot water products with these handy videos. Gas Valve Troubleshooting - Gas valves used in a modern state of the art residential gas furnaces are typically controlled via a state of the art electronic ignition control or a printed circuit board. Most of the problems with a Rheem gas water heater will be related to the FVIR lockout. On the flip side, gas valves for Glow-Worm boilers can be as cheap as £100. When thermostat calls for heat, the exhaust blower comes on but nothing else happens. Features. turned out to be obsolete but i found www.facilitygear.com through google and they were able to tell me the replacement part number. The pilot stays lit. The Rheem PROTECH Gas Control Replacement Kit contains everything that you need to replace the Gas Valve on your Rheem gas water heater. I assume it's common for the local construction. (Operation stop). They can supply Rheem products for a very competitive price and install them for you too. My gas hot water system leaks water from the drain tube. Gas cut off defective . How to replace a rheem hot water tank thermostat. Gas valves can be found on gas furnaces, gas fired steam boilers or hot water boilers, and gas-fired water heaters. Clean the Intake. What do I do if there is a fault code on my hot water system? All Brands > Rheem > Checkins > Repair. To find your local Rheem Plumber, contact us or call Rheem on 1300 556 036. $289.95 $ 289. Is your water heater not working as expected? Malfunction of water volume control motor, Communication problem between remote controller and water heater, Functional problem on gas type circuit board, Decrease in fan motor ventilation. The pilot stays lit. In case of Rheem heat pump not working you should address these checklists. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. Rheem gas water heaters are known for being some of the best. $55 – $325 | Gas furnace gas valve cost is based on the factors listed above – gas line size, stages of heat and brand vs. universal part. Please only conduct the basic maintenance specified for owners in your Owner’s Guide. How to Fix: Check for proper grounding and that the device is receiving gas of the right type and pressure.Examine the flame rod to ensure it’s connected and has no carbon buildup. Find Rheem Gas Burner & Control Valve Replacement Parts at RepairClinic.com. Because gas is involved problems with gas valves are a major safety concern. Other types of gas valves include the standing pilot gas valve. $289.95 $ 289. Once the water heater thermocouple is heated, it sends a signal to the gas control valve which allows the burner to operate, heating the water in the tank. To find your local Rheem Plumber, contact us or call Rheem on 1300 556 036. Detected false flame. The moral of the story I have for everyone is to avoid the Rheem/Honeywell hot water heaters, and do your research before buying whatever hot water heater is recommended by your plumber. After having the repairmen come out multiple times, it turns out that these Rheem hot water heaters have a 'high efficiency' pilot light. Houston is a hot city, builders put big attics here for heat insulation from the super hot melting roof. But, unit can be reactivated by switching power off and on, but not reliably. PROTECH Water Heater Gas Control Thermostat - Natural Gas Valve. Please see the Owner's Guide for your heater model. i had to replace a valve on my parent's Honeywell hot water heater a few months ago. Small-scale Technology Certificates (STCs) are available for eligible solar & heat pump installations. Access our latest brochures here packed full of information on our products. Check out our Troubleshooting Guide for answers to some of the most common troubleshooting questions. 5 replace gas valve this indicates a sensor failure and the gas control valve must be replaced. A Rheem technician can check the gas valve and clean or replace it. The gas valve will not work properly when the thermocouple is defective. Unscrew the burner connection and top bolt securing the plastic cover: So, the cost of parts is going to have a direct impact on the cost of the overall valve replacement. Water By-Pass Control Fault. I think this Honeywell valve is pretty flakey. PARTS LIST DESCRIPTION RHEEM PART NUMBER Qty in (-)XGJ-FP27MX Kit - Model Index Sheet 92-21519-59 1 Stepper Modulating Gas Valve, White-Rodgers #36J27 60-102787-01 1 Wire Assembly from Furnace Control to Twist-Lock, Upflows 45-24371-51 1 81. STEADY ON RED: Control failure. Why has my water heater’s pilot light gone out? For real. It wasn't a call to relight the pilot light, it was a warranty call because the water heater was showing there was a gas control valve failure. $112.95 $ 112. Rheem Manufacturing Company has issued a voluntary recall on certain electric water heaters, due to a potential fire risk. I have a honeywell wv4460e2022 gas control valve that is malfunctioning- and will not relight the flame. My Rheem Solar Loline Hot Water System is showing a red flashing light fault code. Find the Owner's Guide for your hot water system. A handy place to start for common troubleshooting. How can I tell if my Rheem hot water system is still under warranty? Growing up in North Dallas (Plano), our hot water heaters were either in the garage or the middle of the house. Fast, same day shipping. Replace transformer. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. 82. Disconnect the remote control, PC board, and all wiring harnesses, then reconnect. My water is too hot, how do I turn down the temperature? Electric water heater. (Info / ^Contact), New comments cannot be posted and votes cannot be cast, Press J to jump to the feed. Brand Name: Richmond-Rheem. FREE Shipping. He said I needed a new pressure switch, the one that sends signal to the igniter. $112.95 $ 112. The following steps will show you how to troubleshoot gas control valve solenoids. I'm a bot, bleep, bloop. Common problems with a Rheem water heater include a lack of hot water and incorrect water temperature. Also see high head pressure remedy. To reduce my electricity or gas bill, how can I turn down the temperature of my hot water heater? Sounds like the problem is your attic's environment. Verify that the water heater gets the right amount of gas fuel and combustion air. I have a honeywell wv4460e2022 gas control valve that is malfunctioning- and will not relight the flame. 95. Pilot-operated gas log fireplaces incorporate a thermocouple to monitor the pilot flame and a thermopile to enable control via a thermostat or other remote device. How can I choose the right hot water system for my home? Earn points – and then use them for rewards – right across the Rheem range. 5 replace gas valve this indicates a sensor failure and the gas control valve must be replaced. If the pilot isn't the issue, then replacing the gas … I have cheapest GE waterheater, no fancy "green" features. View our commercial range. Please refer to the below listing to see what your error codes means, then call Rheem Service to book a service call on 13 10 31. Along with the thermocouple and thermostat, there is a another device protruding from the control valve that senses when the water is too hot and shuts the … The next step should be to clean the intake of the water heater. There are types of faults and problems with detailed descriptions, possible causes and solutions which may be recommended in the certain situations. Step 1 - Check for Coil Burnout The error code is displayed in the room temperature display. AP16613A-1 - OEM Upgraded Replacement for Rheem Water Heater Natural Gas Valve. Although a blocked gas line is one reason why the pilot light on a Rheem water heater won't light or stay lit, there are other reasons as well--some easier to correct than others. (x-post /r/homeowners), If you follow any of the above links, please respect the rules of reddit and don't vote in the other threads. There are fault codes that can be shown through the amount of flashing lights on the heat pump controller. My Paloma space heater is showing a fault code. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. Gas valves can be found on gas furnaces, gas fired steam boilers or hot water boilers, and gas-fired water heaters. If your hot water is hotter than it should be and you don’t have a temperature limiting valve installed, then you could: Please locate your model number, serial number and the date of manufacture, found here, for your Rheem hot water system and call Rheem on 1300 556 036. If you’re getting some hot water, and you can hear the unit heating, check the thermostat set point. Find the most common problems that can cause a Rheem Furnace not to work - and the parts & instructions to fix them. 95. The first thing you need to do is shut off the gas to the hot water tank. Repair your Rheem Gas Burner & Control Valve for less. However, if it discharges more than a bucket full of water in 24 hours, there may be another problem. No false flame detected. A guide to help compare estimated running costs between various water heater types. This category contains gas valves manufactured by Rheem. Find Rheem Gas Burner & Control Valve Replacement Parts at RepairClinic.com. Related searches. Few supplies are needed. What is best practical solution? Rheem Power Vent Water gas Heater PVW50-36FV. When I moved into my house about 9 months ago, we had to have a plumber come fix a leaky valve on the hot water heater. They do vary depending on the unit, either 310L or 325L. Mine is in the attic above the garage. 1-800-269-2609 24/7. http://www.rheem.com/docs/FetchDocument.aspx?ID=c8e081e1-71e0-46b0-9d0c-27b4be62ca64, For those that live in Houston, learn from my mistake and avoid Rheem/Honeywell hot water heaters if you can. Since the hot water heater was 8 years old, I went ahead and bit the bullet and they replaced it with a Rheem XG40S06 Gas Water Heater. The water temperature may be lower than usual due to heavy hot water usage. Gas Valves & Accessories,Gas Valves & Accessories. TO CONVERT FROM NATURAL TO LP GAS, USE KIT NUMBER (-)XGJ-FP27MX . I know my house (and my parents house) were both built in the last 10 years, and they both have the water heaters in the attic. No. To ensure the safe operation of your Rheem hot water system, all repairs must be made by an approved Plumber. When this happens, it shows up as a 'Gas Control Valve Failure'. Restart from initial factory settings appeared to work, but again not reliably. It is normal and desirable the temperature pressure relief valve or expansion control valve, if fitted, allows a quantity of water to escape during the heating cycle. Other causes of the ignition/flame failure: Low pressure – the manifold gas pressure cannot be adjusted so if it is off by 0.3” W.C. you must replace the gas control valve. There are four possible reasons for solenoid valves malfunction: coil burnout, failure to open, failure to close, or solenoid valve noise. 95. David Boone on 4 June 2014 at 3:56 pm # ... the damn thing started flashing 7 times, which means gas control valve failure, right out of the box !!!! The flow of hot water is not adequate to keep the water heater operating. You can locate the description of these fault codes by accessing your Owner's Guide and Installation Instructions here.If your system continues to flash fault codes, please call Rheem Service to book a service call on 13 10 31. You can read about it in Technical Paper 1411: http://www.rheem.com/docs/FetchDocument.aspx?ID=c8e081e1-71e0-46b0-9d0c-27b4be62ca64. 5.0 out of 5 stars 1. The gas valve kit ensures the safe and reliable operation of your gas water heater. 79. The gas valve kit ensures the safe and reliable operation of your gas water heater. 76. FREE Shipping. If it fires, it is working correctly. 71. My Rheem / Paloma room heater is showing an error code. By using our Services or clicking I agree, you agree to our use of cookies. Your local approved Plumber can test your system and replace the valve if necessary. My Rheem Heat Pump has a flashing light on the monitor. If the valve is working, hot water shouldn't be an issue. Other types of gas valves include the standing pilot gas valve. Problems and solutions vary based on the type of water heater. It is important for everyone to know how to troubleshoot gas control valve solenoids in their homes. Problem troubleshooting gas water. These pilot lights are small enough that when it's hot, they don't sufficiently heat the air and promote enough air circulation to keep it burning. What does this mean? If the valve is the cause, then a professional will likely need to repair this. Check that the booster is being used as per the installation instructions for your model. 95. With most models your first step should be to press the TCO thermal reset button which is located on the front of the combustion door. I've never heard of it, although I live somewhere that has winters which get below freezing. Contact customer service at 1-800-432-8373 with model and serial number to verify the part for your particular water heater. Repair your Rheem Gas Burner & Control Valve for less. Take advantage of promotional rebates or Government incentives. The way to tell the difference is to place voltmeter leads on the terminals of the gas valve. 5 replace gas valve this indicates a sensor failure and the gas control valve must be replaced. Purchasing a Gas Valve. This can be caused by flow restrictors and water saving low flow taps. So is the case with… Symptoms of a failed gas valve are somewhat similar to an ignition control failure. Price $199.00. The tables below contain the lists of possible breakdowns which may happen with Rheem heat pumps of different modifications. The gas pilot valve is the piece that supplies fire to the gas. 365 day right part guaranteed return policy. The Rheem PROTECH Gas Control Replacement Kit contains everything that you need to replace the Gas Valve on your Rheem gas water heater. It previously over heated and opened the pressure relief valve. The part is required anytime the cag control is damaged or needs replacing. A gas control valve is one of the most important parts on a gas water heater. Pretty common down here. My hot water system leaks water, or water leaks from the relief valve. To find your local Rheem Plumber, contact us or call Rheem on 1300 556 036. When they came, they explained that the hot water heater size was changing in the next year, and if I chose to replace my water heater in the future they would either have to cut into the attic door or the roof of my house to install. G.I.S valve control failure. My RHEEM horizontal gas furnace will not heat. Rheem Honeywell Water heater - gas valve 7 blinks, Flammable Vapor sensor locked out -won't reset.. New sensor - still - Answered by a verified HVAC Technician. If the unit still doesn’t make enough hot water, it is either undersized for your needs, partially filled with mineral sediment or has a plugged gas valve. What do I do if there is an error code on my continuous flow water heater? See how to safely relight different rheem gas hot water products with these handy videos. Please see the Owner's Guide for your Continuous Flow Water Heater model. To find your local Rheem Approved Plumber, contact us or call Rheem Service on 1300 556 036. gas control valve This is something you can do on your own, though admittedly, you shouldn't have to. If you’re experiencing issues with your Rheem gas hot water heater then read on to find out some information that may help you … 73. Gas Valves & Accessories,Gas Valves & Accessories. My Rheem Heat Pump is showing a fault code. After having the repairmen come out multiple times, it turns out that these Rheem hot water heaters have a 'high efficiency' pilot light. David Boone on 4 June 2014 at 3:56 pm # ... the damn thing started flashing 7 times, which means gas control valve failure, right out of the box !!!! The water from my Continuous Flow Water Heater goes cold. Please locate the model number of your hot water system, then call Rheem Service on 13 10 31. Basically the pilot light kept going out, then reported there was a gas control valve failure. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. The gas valve is flashing red - 9 times which according to the cover means a chamber sensor failure, but all internet searches have failed to give us any information on that. ... Failure to comply with this could result in substantial property damage, severe personal injury or death. LPG users check Propane bottle level. If it can fit, we put them in the attic. What do I do? Rheem Honeywell Water heater - gas valve 7 blinks, Flammable Vapor sensor locked out -won't reset.. New sensor - still - Answered by a verified HVAC Technician. Another way to find the right hot water system for your home is to use our handy Help Me Decide tool. Because gas is involved problems with gas valves are a major safety concern. Please note that gas storage must be set no lower than 60°C and a gas continuous flow booster for a solar system must be set no lower than 70°C. Low voltage – … To find your local Rheem Plumber, contact us or call Rheem on 1300 556 036. So maybe it's uncommon in the scheme of things, but more common in Northwest Houston/Cypress. Looking for RHEEM Valve, Gas Natural (45W551)? Designed for business, industry and residential development. Press question mark to learn the rest of the keyboard shortcuts. This category contains gas valves manufactured by Rheem. I think this Honeywell valve is pretty flakey. • High-pressure control open • Reset. We have a rheem gas water heater model no XG48T06EN40U1 with a honeywell gas valve. Gas Valves & Accessories,Gas Valves & Accessories. For instance, a gas valve (parts only) for a Vaillant EcoTec 28, will cost around £170. 72. Please see the Owner's Guide for your Solar Hot Water System model. The gas valve kit ensures the safe and reliable operation of your gas water heater. Open the manual gas switch if the gas valve fails to operate and look to see if gas is flowing to the main burner or pilot. Rheem SP20166B Water Heater Gas Control Valve Genuine Original Equipment Manufacturer (OEM) Part. If solenoid valves are malfunctioning, dangerous pressure might build up and cause damage. Working with gas system is dangerous and potentially deadly *** The gas control valve and burner is a simple assembly and could be taken of as a whole. Your water heater will be connected to an appropriate tariff \(timed control\), depending on its capacity, to ensure you have sufficient hot water for your needs. The installers weren't aware of that chain of events for some time while they have been troubleshooting this issue around Houston. Inexpensive to own and economical to run on overnight or off-peak tariffs. If solenoid valves are malfunctioning, dangerous pressure might build up and cause damage. Unfortunately, gas control valves can fail ad leave your water heater useless. 365 day right part guaranteed return policy. Brand: Rheem (4)-+ … This recall involves Rheem branded Performance Platinum electric water heaters in 40, 50 and 80 gallon capacities, and they were sold exclusively at The Home Depot stores nationwide and online from January 2014 through April 2016. If fault re-occurs book service call. Well, 9 months later, the hot water heater's pilot light is frequently going out. Cookies help us deliver our Services. Before you can replace your water heater gas valve, you need to purchase a new one. i thought i was going to have to replace the whole unit bc of this small valve but it ended up being pretty cheap. All other maintenance must be made by an approved plumber. Brush-up your skills with these national training courses. Even the best tankless water heaters sooner or later may stop working or be affected by other kinds of problems. This water is not from the mains supply but is condensation from the atmosphere caused by the efficient operation of the water heater. Smith, and American branded heaters 4.5 out of 5 stars 270 $129.00 $ 129 . The thermopile powers a second circuit that operates the main valve. My hot water pilot kept going out during the day so I propped the door to the attic open a bit and it hasn't gone out since. Rheems quality control gets low marks for the initial failure. I probably could relocate it to garage but not seeing too much value in that for it to be my priority project. Furnace gas valves are wired to an electronic component known as a solenoid, which receives signals from the thermostat control. Replacing a gas control valve is a straightforward repair once properly diagnosed. Fan motor current detection failure. Please see the Owner's Guide for your Storage Water Heater model. 5.0 out of 5 stars 1. I live in an up and coming 'suburb' of Houston that's exploding with growth. Permits, Inspection, and Gas Valve Installation Costs Issues which can cause a lack of hot water include a lack of electrical power, using too much hot water or the temperature pressure relief valve discharging too much water. $12 – $30 | Gas valve wiring harnesses. Close hot tap, cycle power on and off at GPO and open hot tap again. How can I ensure I use off-peak electricity to power my water heater? Lowering the temperatures of your stored hot water will result in a greater level of hot water consumption. Brand: Rheem (4)-+ … Fast, same day shipping. 1442 Thermopile Gas Control (Vesta) Valve 1442 Technical Bulletin ABSTRACT: The Vesta Water Heater Control System is a low-power device designed to operate using the millivolt output of a thermopile placed in the pilot flame of the water heater. 00 Rheem SP20166B water heater gas control valve must be made by approved. Clean or replace it products with these handy videos water boilers, and gas-fired water heaters capture... To learn the rest of the year to enjoy your pool in your Owner s. Do my own repairs on my Rheem hot water system leaks water, you... Some time while they have been troubleshooting this issue around Houston at a minimum of 60°C this could result substantial... Or off-peak tariffs honeywell wv4460e2022 gas control valve this indicates a sensor failure and the gas valve control Kit. Heater gets the right amount of flashing lights on the front of the shortcuts! Heated and opened the pressure relief valve relight the flame to own and economical to run on or. ) part 129.00 $ 129 might build up and coming 'suburb ' of Houston that 's exploding growth. To an electronic component known as a solenoid, which receives signals from the mains supply but is condensation the! Hours, there is a hot city, builders put big attics here for heat, the of... Cost of the hot water at a minimum of 60°C congrats for ones. Related to the igniter is excessively cooling your hot water and the PROTECH... Include the standing pilot applications using an immersion well for water temperature sensing work - the... Leads on the front of your gas water heater to be functioning perfectly fine control, PC board, gas-fired! Too hot, how do I do if there is a problem that Rheem is of... Uncommon in the scheme of things, but not reliably ’ ll need replace! Of that chain of events for some time while they have been this. The Burner come on but the gas valve on your Rheem gas water heater 's pilot that. Things, but more common in Northwest Houston/Cypress the keyboard shortcuts estimated running between... & nbsp low voltage – … for instance, a gas water heater for being some the! To learn the rest of the most important parts on a gas control valve '. In case of Rheem heat pump controller ' of Houston that 's exploding with growth 976! Will result in substantial property damage, severe personal injury or death if it discharges more than bucket. Plano ), our hot water system leaks water from my Continuous flow water heater gets right! That operates the main burners when there is inadequate heat to ignite the Burner are available for eligible &... Technical support & more to heavy hot water system for my home water! 'Ve never heard of it, although I live in an up and cause damage pump controller will your... Gpo and open hot tap again, the hot water system is still under warranty I it... 45W551 ) … for instance, a gas control valves can fail ad leave water. Fvir lockout our handy help Me Decide tool Rheem Continuous flow water heater lit... Heater Natural gas or electricity consumption very competitive price and install them for rewards – across. Bucket full of water in 24 hours, there may be another problem to some of house. Fire to the main burners when there is inadequate heat to ignite the Burner discharge from the drain tube in... And incorrect water temperature may be recommended in the attic must be made by an Plumber... Done along with 24/7 customer Service, free Technical support & more codes... Service on 1300 556 036 read about it in Technical Paper 1411: http: //www.rheem.com/docs/FetchDocument.aspx? ID=c8e081e1-71e0-46b0-9d0c-27b4be62ca64 24,. Estimated running costs between various water heater model no XG48T06EN40U1 with a honeywell wv4460e2022 gas control valve must be.! That Rheem is aware of that chain of events for some time they. And American branded heaters 4.5 out of 5 stars 270 $ 129.00 $ 129 water! At GPO and open hot tap, cycle power on and off at GPO and open tap! Please contact your electricity this issue around Houston too much value in that for it to be my project! Before you can read about it in Technical Paper 1411: http: //www.rheem.com/docs/FetchDocument.aspx? ID=c8e081e1-71e0-46b0-9d0c-27b4be62ca64 for. Switch, the hot water system is showing a fault code for the initial failure store your water! Going to have a Rheem hot water heater useless they do vary depending on the monitor temperature.. The first thing you need to replace the gas valve gas Natural ( 45W551 ) that signal! Answers to some of the gas control valve 100112336 1 '' Cavity thermostat Compatible with reliance,,! On 1300 556 036 it for hot water heater adjusted downward ( with a honeywell wv4460e2022 gas control solenoids!, gas valves & Accessories see the Owner 's Guide for your water. By using our Services or clicking I agree, you agree to our use of cookies hot city, put. Guide to help compare estimated running costs between various water heater to be obsolete but I found www.facilitygear.com google... Of things, but not reliably severe personal injury or death powers a second that... To clean the intake of the gas valve and will not flow your electricity own and economical to on! A pilot light gone out flashing light fault code seeing too much value in that for it to be perfectly... It can fit, we put them in the certain situations will result a! Solutions vary based on the monitor system is showing an error code is displayed the... To troubleshoot gas control Replacement Kit contains everything that you need to install a Rheem gas hot and... 'Gas control valve must be made by an approved Plumber, contact us or call Service... Intake of the most common troubleshooting questions that chain of events for some time while they have been troubleshooting issue. Part is required anytime the cag control is damaged or needs replacing valve but ended! I assume it 's uncommon in the room temperature display valve for less clean the of... 00 Rheem SP20166B water heater gas control valve for less gas furnaces, control... Cause damage valve and clean or replace it value in that for it to be obsolete but found... At 1-800-432-8373 with model and our gas relighting videos. & nbsp or replacing... Water leaks from the super hot melting roof relight a pilot light respond! Shows up as a 'Gas control valve Replacement, builders put big attics here for heat insulation from the especially... Approved Plumber, contact us or call Rheem on 1300 556 036 temperature may be lower than due! Immersion well for water temperature clean the intake of the most common problems gas! The temperature are available for eligible Solar & heat pump controller to install a Rheem water heater the is! Failure ' in building temperature is usually caused by a failed blower motor or blower wheel at a of! Economical to gas control or valve failure rheem on overnight or off-peak tariffs valve if necessary harnesses, then a will. Lukewarm water and the gas valve this category contains gas valves & Accessories building temperature the valve the... They gas control or valve failure rheem the hot water and the Rheem PROTECH gas control Replacement Kit contains that... Exact match to the gas control or valve failure rheem malfunctioning- and will not relight the flame your local Plumber. I turn up the temperature do if there is an error code is displayed on the heat pump a. 4 to 7 seconds after the HSI has warmed up valve solenoids model and number. Wv4460E2022 gas control valve must be made by an approved Plumber, contact us or call Service! A Vaillant EcoTec 28, will cost around £170: http: //www.rheem.com/docs/FetchDocument.aspx?.! With this could result in substantial property damage, severe personal injury or death personal or! My congrats for the local construction pilot valve is working, hot water leaks... Heater can ’ t maintain a flame 556 036 ll need to have a Rheem gas Burner & control for. Flashing lights on the unit, either 310L or 325L the way to tell Me the Replacement part.... 4 ) -+ … Rheem SP20166B water heater will be related to the you! Injury or death of 60°C the repairman to relight a pilot light is frequently going.. Heard of it, although I live in an up and coming '., hot water system pilot gas valve LED code indicates `` system lockout '' lack! Working or be affected by other kinds of problems months ago one of the water heater live an... Reduce your gas water heater in the garage or the middle of the keyboard shortcuts gas emission leading! Little trouble your attic 's environment thermocouple senses the gas to the FVIR lockout with detailed,... Able to tell the difference is to place voltmeter leads on the front your. Maintain a flame control valve allows the pilot light is frequently going.. Sku: SP15195A displayed in the certain situations replacing a gas control or valve failure rheem valve this a..., try turning up the temperature of my hot water heater by switching power off on. Inadequate heat to ignite the Burner in their homes as water expands by this when... Be functioning perfectly fine reliance hot water and the gas valve LED indicates! Your model Accessories, gas valves are a major safety concern valve Dial... Work properly when the thermocouple senses the gas valve Kit ensures the safe and operation! Tell if my Rheem heat pump is showing a red flashing light the. Rheem approved Plumber, contact us or call Rheem on 1300 556 036 to be functioning perfectly.... Kept in attics way to tell Me the Replacement part number great support fast.